PNAClamp™ Mutation Detection Kit EGFR (ver.2)
Ref. PNAC-3002Lung cancer is categorized into two types; non-small cell lung cancer (NSCLC) with the 80~85% frequency and small cell lung cancer with the 15~20% frequency. Epidermal growth factor receptor (EGFR) is expressed on the surface of epidermal cells and has the tyrosine kinase activity.
About the Product
Lung cancer is categorized into two types; non-small cell lung cancer (NSCLC) with the 80~85% frequency and small cell lung cancer with the 15~20% frequency. Epidermal growth factor receptor (EGFR) is expressed on the surface of epidermal cells and has the tyrosine kinase activity. Overexpression of EGFR is found only in NSCLC and may lead to signal transduction system in cells by causing cell proliferation, tumor-induced neoangiogenesis (formation of new blood vessels) and transition induction. The EGFR tyrosine kinase inhibitor (TKI), gefinitib (Iressa, AstraZenca) or erlotinib (Tarceba, Roche), is effective to inhibit the growth of cancer cells and leads to death of cancer cells and suppression of new blood vessels in lung cancer tissue. Especially, some specific mutations in the ATP-binding domain of EGFR gene have strong positive correlation with the response rate of EGFR-TKIs. Furthermore, NSCLC patients with the EGFR mutations are reported to be more effective to EGFR-TKI and show prolonged survival rate of patients with lung cancer. Therefore, detection of the EGFR mutation is becoming an important prognostic biomarker for drug response, and efficient detection of the EGFR mutation is expected to be highly helpful for increase of survival rate of patients with lung cancer in targeted therapy.
Total 40 EGFR mutations can be detected.
Technical Characteristics
| Exon 18 - G719X | 3 |
|---|---|
| Exon 19 - E19del | 26 |
| Exon 20 - T790M | 1 |
| Exon 20 - S768I | 1 |
| Exon 20 - E20ins | 6 |
| Exon 21 - L858R | 2 |
| Exon 21 - L861Q | 1 |
| Total mutations | 40 |
| Detection limit | 1% LOD with 25 ng wild/mutant type mixed DNA |
| Running time | within 3 hours |
| Procedure | sample preparationExtraction of Total DNAAmplification of target DNA by Real-Time PCRAnalysis of Result |
Key Features
- High sensitivity and specificity even with small amount of DNA (1% LOD with 25 ng wild/mutant type mixed DNA)
- Real-Time PCR based ready-to-use kit
- Short running time (within 3 hours)
Technical Information
No technical information available for this product.
Compatibility
Compatible sample type:
- FFPE tissue
- Fresh tissue
- Biopsy tissue
Compatible Real-Time PCR machine:
- CFX96 (Bio-Rad)
- LightCycler 480II (Roche)
- ABI7500 (Thermo Fisher Scientific)
- ABI7900HT (Thermo Fisher Scientific)
- Rotor-Gene Q (Qiagen)
Packaging
25 tests